Heat Pumps
Poolex IceSpa 7kW Inverter Heat Pump for Spas and Hot Tubs
The IceSpa 7kW is a plug & play full Inverter heat pump for spas especially designed for cold climates, at -10°C air and 38°C water temperature, heat output is still 3.3kW thanks to the EVI (Enhanced Vapour Injection) compressor. In fact with a COP of 2.2, even at -10°C, the IceSpa is two times cheaper than the electric heater to run.
EVI (Enhanced Vapour Injection) improves the energy efficiency of refrigeration and air conditioning systems by injecting additional vapor into the compressor at low temperatures. It is thanks to this innovative technology that the IceSpa is able to perform so well in extreme weather conditions.
Operating down to -25°C, you can heat up your spa or hot tub in the middle of winter, the Full Inverter technology will reduce your energy consumption up to 75% at an equivalent power consumption compared to an electric heater.
Easy to install, the IceSpa is compatible with all hot tubs and connects itself as easily. Ideal for swim spas and Nordic baths, this heat pump will exceed your expectations.
The IceSpa features Wi-Fi temperature control and a programmable timer using the dedicated Poolex App, available for iOS and Android smart devices. A colour touchscreen that can be detached from the unit (wired) can be added as an option.
Key features
- The power of Full Inverter & EVI efficiency right down to -25°C
- Up to 7kW of heat output at air temperature of 26°C and water temperature of 26°C
- Up to 4.7kW of heat output at air temperature of 15°C, water temperature of 38°C
- Up to 3.3kW of heat output at air temperature of -10°C, water temperature of 38°C
- Can be installed on any type of spa, hot tub, swim spa or Nordic bath (size dependent)
- Operates down to -25°C, automatic de-icing
- Reversible hot/cold for ultimate flexibility, can be used to heat or cool
- Heating range from 15 – 40°C, cooling range from 4 – 35°C
- Wi-Fi for easy remote control via the dedicated Poolex app, available for both iOS and Android smartphones
- Plug and play, comes with 4m mains cable and RCD plug (please note RCD plug will not fit outdoor sockets with covers)
- 32/38mm hose tail water connections, pipes and/or other fittings not supplied
- Integrated control of the spa / hot tub heater and/or auxiliary heat pump (relay/s optional)
- R32 Refrigerant
- Supplied with RCD mains cable, anti-vibration pads, 32/38mm hose tails, 2 x hose clips and winter cover
- Three year parts warranty, seven year parts (total) on compressor and 15 year corrosion (total) on Titanium coil
Fitting a heat pump to your Hot Tub can reduce running costs by up to 75%, and reduce heat up time by half.
These results can only be achieved if you fit the correct heat pump. There are many heat pumps on the market that are too small and are designed to take the chill off above ground splash pools, operating at 26/28c, whereas a Hot Tub runs at 38/40c. They rely on the Hot Tub heater as a back up, and in milder weather the heater will be required almost constantly, therefore will not give anywhere near the energy savings promised. You’re sold the idea of a heat pump but without the performance.
The minimum size of heat pump recommended for a 2mt or 2.3mt Hot Tub is 7kw, anything smaller simply won’t work efficiently in the Irish climate.
We at the Hot Tub Centre highly recommend the ice spa 7kw heat pump which is specifically designed for Hot Tubs.
For rental properties the correct heat pump will save money and facilitate turn around time.
FITTING THE WRONG HEAT PUMP IS SIMPLY A WASTE OF MONEY.
heat Pump Prices
O’SPA 3KW – £645-00
O’SPA 5KW – £920-00
O’SPA 7KW – £1,100-00
ICE SPA 7KW – £1,800-00
All the O’Spa range of heat pumps require the Hot Tub Heater to remain connected as either the back up or main heat source.
The Ice Spa heat pump is fitted as the only heat source
3KW O’SPA – Not suitable for Hot Tubs, used mostly as a cooler in ice-baths.
5KW O’SPA – For use in smaller Hot Tubs,but will not be capable of providing all the heat required,will need the assistance of the Hot Tub heater. It will reduce the running costs, but only slightly, and during the colder months, hardly at all.
7KW O’SPA – Works reasonably well but isn’t as effective as the ice Spa. The Hot Tub heater is left connected so when heating, both the Tub heater and the Heat Pump are heating at the same time. Should give around 50% during warmer months, but efficiency will drop as the temperature drops. It works to a temperature of + 5 degrees wheras the Ice Spa works down to -10 degrees. Running costs will be reduced but not anything like expected, and much less than the Ice Spa Heat Pump.
7KW ICE SPA – We have monitored the performance of this Heat Pump over the last year. It heats the tub up in half the time at a third of the cost, and maintains the water temperature better than the tub heater itself. The Ice Spa Heat Pump reduces the running costs by 65/70%. The tub heater is disconnected, so the Heat Pump is the only heat source. There is a Wifi connection which allows the customer to monitor the tub settings remotely. In a holiday let situation we can leave the tub heater connected, using the Wifi the tub heater can be turned on and off remotely. This means the tub heater and the Pump Heater can be heating at the same time, giving up to 6kw heating, the tub heater can be turned off leaving the Heat Pump to take over on it’s own. THIS HEAT PUMP REALLY WORKS WELL The pay back time with the 7kw Ice Spa is much shorter and savings in the long term much higher. Initially more expensive but in the long term more cost effective.
- 7kw ICE SPA Heat Pump - £1800
- Pipework, Valve kit & Insulation - £200
- Delivery & Installation - From £400
Specifications
| Heating Capacity A26/W26 | 3.3~7kW |
| Power consumption | 0.28~1.4kW |
| COP | 5~11.9 |
| Heating Capacity A15/W38 | 2.8~4.7kW |
| Power consumption | 0.67~1.3kW |
| COP | 3.7~4.2 |
| Heating Capacity A-10/W38 | 2.2~3.3kW |
| Power consumption | 1.2~1.5kW |
| COP | 1.8~2.1 |
| Maximum Power | 1.7kW |
| Voltage | 230v |
| Noise Level (10m) | <28dB(A) |
| Refrigerant | R32 |
| Water Connections | 1″ male / 32-38mm |
| Nominal Flow | 3m³/h |
| Dimensions (L x W x H) | 710mm x 490mm x 500mm |
What is COP?
- COP stands for Coefficient of Performance
- COP is quoted as a number, such as 7
- For each kW of energy input, 7 x kW would be output
- The higher the output, the lower the running costs
Installation
Connections
All models are fitted with a 4m mains cable and RCD plug as standard (please note RCD plug will not fit outdoor sockets with covers).
Water inlet and outlet connections are 1 inch / 32-38mm, two hose tails are supplied as standard, however you may require additional hose and fittings to connect to your spa or hot tub. The IceSpa should be connected after your spa’s circulation pump and heater, the use of a bypass kit (normally made up of 2 x T-pieces and 3 x ball valves) is recommended.
Supplied with RCD mains cable, anti-vibration pads, 2 x 1″ / 32-38mm hose tails, 2 x hose clips and winter cover
All models are fitted with a 4m mains cable and RCD plug as standard (please note RCD plug will not fit outdoor sockets with covers).
Water inlet and outlet connections are 1 inch / 32-38mm, two hose tails are supplied as standard, however you may require additional hose and fittings to connect to your spa or hot tub. The IceSpa should be connected after your spa’s circulation pump and heater, the use of a bypass kit (normally made up of 2 x T-pieces and 3 x ball valves) is recommended.
Supplied with RCD mains cable, anti-vibration pads, 2 x 1″ / 32-38mm hose tails, 2 x hose clips and winter cover
Wi-Fi
Positioning
Your Poolex IceSpa heat pump should always be installed outside, restrictions on air flow around a heat pump such as dense vegetation or solid surfaces such as sheds, fences or walls will lead to a drop in efficiency and heating ability, it especially important that cooled air can be properly dispersed away from the unit.
While the casing provides protection from the weather, the IceSpa should be disconnected and stored in a shed or garage if not in use for extended periods.